Experience with a steady-state heat-transfer technique in a large wind-tunnel

Show simple item record

dc.contributor.author K. G. Winter en_US
dc.contributor.author L. Gaudet en_US
dc.contributor.author T. G. Gell en_US
dc.date.accessioned 2014-10-21T15:51:27Z
dc.date.available 2014-10-21T15:51:27Z
dc.date.issued 1975 en_US
dc.identifier.other ARC/R&M-3797 en_US
dc.identifier.uri https://reports.aerade.cranfield.ac.uk/handle/1826.2/3076
dc.description.abstract The Report covers the design and development of a plant for pumping a liquid through a model so as to control its temperature, the design and manufacture of the model, and the development of the heat-flow meters used in the model and the means of calibrating them. Sample measurements of heat transfer on the model, a rhombic cone of unit aspect ratio at a Mach number of 2.45, are shown and compared with calculated values. en_US
dc.relation.ispartofseries Aeronautical Research Council Reports & Memoranda en_US
dc.title Experience with a steady-state heat-transfer technique in a large wind-tunnel en_US