A discussion of pitot-static tubes and of their calibration factors with a description if various versions of a new design

Show simple item record

dc.contributor.author C. Salter en_US
dc.contributor.author J. J. Warsap en_US
dc.contributor.author D. G. Goodman en_US
dc.date.accessioned 2014-10-21T15:56:07Z
dc.date.available 2014-10-21T15:56:07Z
dc.date.issued 1962 en_US
dc.identifier.other ARC/R&M-3365 en_US
dc.identifier.uri https://reports.aerade.cranfield.ac.uk/handle/1826.2/3948
dc.description.abstract The report describes experiments devised to investigate some of the previously unexplained peculiarities of normal types of pitot-static tube. Revised basic calibration factors for various instruments are recorded. In the process use was made of a special design of standard static-pressure tube and the experiments led to new alternative types ofpi~ot-static and plain static-pressure instruments. These have nose profiles of modified-ellipsoidal shape. In the report particular attention is given to the implications of the term 'calibration factor', to the special features and limitations of various types of instrument, to the details and precautions of experimental technique for reliable investigations and to the inclusion of generally associated information and comment. en_US
dc.relation.ispartofseries Aeronautical Research Council Reports & Memoranda en_US
dc.title A discussion of pitot-static tubes and of their calibration factors with a description if various versions of a new design en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search AERADE


Browse

My Account