Hockenhull, B. S.
Description:
Considerations are made of the suitability of acoustic transformers
applied to fatigue testing at 20 kH2. A suitable system has been constructed
which allows the use of plain cylindrical specimens. The results of fatigue
tests on an aluminium alloy are given and discussed in relation to structure
and environment.